-
Model : BR7000-T/RS485 Part No. : B44066R7615E230 Dynamic Transistor Outputs Interface RS485 with software Supply voltage : 110-230 V AC Measurement : 3-phase Measurement voltage range : 30-440 V AC (L-N) / 50-760 V AC (L-L) Measurement current (CT) : X/5 and X/1 A possible with Display of system parameters, Alarm output and Recall recorded value Switching voltage of transistor outputs 24 V DC.
-
Model : BR7000-I-TH /Dynamic and Hybrid Relay/Transistor Outputs Part No. : B44066R7412E230 12 transistor and 12 relay outputs Supply voltage : 110-230 V AC Measurement : 1-phase Measurement voltage range : 30-440 V AC (L-N) / 50-760 V AC (L-L) Measurement current (CT) : X/5 and X/1 A possible with Display of system parameters, Alarm output and Recall recorded value Switching voltage of transistor outputs 24 V DC.
-
Model : BR6000-T12 Dynamic Transistor Outputs Part No. : B44066R6112E230 Supply voltage : 110-230 V AC Measurement : 1-phase Measurement voltage range : 30-525 V AC (LN or LL) Measurement current (CT) : X/5 and X/1 A possible with Display of system parameters, Alarm output and Recall recorded value Switching voltage of transistor outputs 10-24 V DC.
-
Model : BR7000-R15/RS485 Part No. : B44066R7415E230 Operating voltage : 110 ... 440 V AC ±10%, 50/60 Hz Measuring voltage (3-phase) : 3 · 30 … 440 V AC (L-N), 50...760Vac (L-L); 50/60 Hz Measuring current : 3 · X: 5A / X:1A selectable Power consumption : < 5 W (with 15 relays activated) Sensitivity : 50 mA/10 mA Relay outputs for capacitor branches : 15 relays, freely programmable for switching of 1- or 3-phase capacitors Interface : 2 independent isolated interfaces RS485 (MODBUS RTU, system interface) Type : 15 steps
-
Model : BR 7000-I/RS485 Part No. : B44066R7012E230 Operating voltage : 110 … 440 V ~ +/- 10 % Measuring voltage : 30 … 440 V ~ (L-N); 50 … 760 V ~ (L-L) Measuring current : X: 5 A / X: 1 A, selectable Power consumption : < 5 VA Sensitivity : 50 mA/10 mA Relay outputs for capacitor branches : 12 Alarm relay / message relay : 1/1* (*only version –I/S485) Switching power of relays : 250 V AC, 1000 W Number of active outputs : Programmable Version BR7000-I/S485 : Interface RS485, for usage with evaluation software BR7000-SOFT, included in the delivery One freely programmable external input, e.g. for 2nd parameter set Type : 12 steps
-
Model : BR 6000 Series ECONOMIC Part No. : B44066R6***R230 supply voltage : 245 V AC ±20%, 50/60 Hz Measurement voltage range : 30 ... 525 V AC (L–L / L–N) Measurement current (CT) : x/5 and x/1 Ampere possible Minimum operating current : 40 mA / 10 mA Maximum current : 5.3 A (sinusoidal) Zero voltage release : < 15 ms Accuracy : Current, voltage : 1% Reactive, active, apparent power: 2% Number of outputs : 6/7 or 12/13 steps available Switching voltage/current : Max. 250 V, 6 A Alarm relay : Potential-free contact (max. 250 V, 6 A) Type : BR6000-R6 , BR6000-R12
-
Model : BR 6000 Series Part No. : B44066R6***E230 Supply voltage : 110…230 V AC ±15%, 50/60 Hz Measurement voltage range : 30 ... 525 V AC (L–L / L–N) Measurement current (CT) : x/5 and x/1 Ampere possible Minimum operating current : 40 mA / 10 mA Maximum current : 5.3 A (sinusoidal) Zero voltage release : < 15 ms Accuracy : Current, voltage: 1% Reactive, active, apparent power: 2% Number of outputs : 6/7 or 12/13 steps available Switching voltage/current : Max. 250 V, 6 A Alarm relay : Potential-free contact (max. 250 V, 6 A) Type : BR6000-R6 , BR6000-R12